Filters
Question type

Study Flashcards

When using , kneel on the hose to anchor as the driver/operator drives slowly toward the water source.


A) supply hose as an attack line
B) individual sections from a flat load
C) hose equipped with wye appliances
D) individual sections from a horseshoe load

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

Which of the following is an example of chemical damage?


A) Buildup of mold and mildew
B) Corrosion of metal couplings
C) Exposure to extreme heat or cold
D) Exposure to motor oil and gasoline

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

What is an advantage of the forward lay?


A) No firefighters are required to stay at the fire hose
B) It is expedient if the apparatus must stay at the water source
C) It allows the hose to be charged more quickly than other hose lays
D) Pumper can remain at the incident scene so hose and equipment are readily available

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

Which hose load finish begins by forming three or more pull loops that extend beyond the end of the hose load?


A) Straight finish
B) Skid load finish
C) Horseshoe finish
D) Reverse horseshoe finish

E) A) and C)
F) None of the above

Correct Answer

verifed

verified

What type of fire hose damage can weaken the jacket which can lead to ruptures under pressure?


A) Organic damage
B) Thermal damage
C) Chemical damage
D) Mechanical damage

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Which of the following tools is required when extending a section of hose?


A) Hose ramp
B) Hose clamp
C) Hydrant wrench
D) Hydrant appliance

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

What type of hose transports water or other agents, at increased pressure, from a pump-equipped apparatus to a nozzle?


A) Attack hose
B) Supply hose
C) Booster hose
D) Pumper hose

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

Which fitting is used to connect a smaller diameter hose to the end of a larger one?


A) Reducer
B) Adapter
C) Strainer
D) Decreaser

E) None of the above
F) A) and D)

Correct Answer

verifed

verified

Which of the following methods could be used to control a loose hoseline?


A) Apply body weight to hose
B) Add a gated wye to the line
C) Close the nozzle as quickly as possible
D) Apply a hose clamp at a stationary point in the hoseline

E) B) and C)
F) None of the above

Correct Answer

verifed

verified

A hose clamp should be applied at least______ feet (m) behind the apparatus.


A) 5 (1.5)
B) 10 (3)
C) 15 (4.5)
D) 20 (6)

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

The test site for service testing should be:


A) on a gravel area.
B) on a slight grade.
C) as close to the station as possible.
D) large enough to lay out hose with multiple kinks.

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

When operating small hoselines with two firefighters, the backup firefighter takes a position behind the nozzle operator.


A) on the same side of the hose about 3 feet (1 m)
B) on the opposite side of the hose about 3 feet (1 m)
C) on the same side of the hose about 6 feet (2 m)
D) on the opposite side of the hose about 6 feet (2 m)

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Which of the following procedures should be followed when service testing fire hose?


A) Close all valves as quickly as possible
B) Pick up all large-diameter hose before charging it
C) Stand away from the discharge valve connection when charging hose
D) Connect the hose to discharges on the pump panel side of the apparatus

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

How should hose be stored in hose racks?


A) Pack hose tightly to ensure a good fit
B) Store hose in direct sunlight whenever possible
C) Roll hose with the male end inside roll to protect male coupling threads
D) Locate hose rack in apparatus room/bay, as close as possible to the apparatus

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Which types of couplings are made of brass or other malleable metals?


A) Cast couplings
B) Inverted couplings
C) Extruded couplings
D) Drop forged couplings

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Which kind of couplings have male and female parts?


A) Sexless couplings
B) Threaded couplings
C) Unthreaded couplings
D) Nonthreaded couplings

E) All of the above
F) A) and C)

Correct Answer

verifed

verified

The guidelines for service testing fire hose are provided in NFPA:


A) 472.
B) 1002.
C) 1620.
D) 1962.

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

For which type of hose lay must hose be loaded into the hose bed in two separate hose bed compartments?


A) Reverse lay
B) Forward lay
C) Apparatus lay
D) Combination lay

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

Showing 41 - 58 of 58

Related Exams

Show Answer